Accommodation Container – AC202

 

8-Room En-Suite Accommodation Building – AC202

 

AC202 is a purpose-built modular accommodation building manufactured by Prefabex, designed with eight private en-suite rooms arranged around a central internal corridor.

The illustrated building measures approximately 9.60 × 13.80 m and provides around 132 m² of organized accommodation space for engineers, supervisors, consultants, staff and other project personnel requiring private rooms with dedicated sanitary facilities.

Its compact single-storey layout makes AC202 suitable for construction camps, infrastructure developments, industrial projects, energy sites and remote project locations where comfortable private accommodation is required close to operations.

AC202 is part of the Accommodation Containers range by Prefabex, developed for staff, engineer and project-site accommodation.

OFFER REQUEST FROM
(Accommodation Container – AC202)











 

Private En-Suite Accommodation for Project Personnel

AC202 is designed for projects where individual room privacy and dedicated sanitary facilities are important.

Eight private accommodation rooms are positioned along both sides of the central corridor, creating a clear and efficient circulation layout while maintaining direct internal access to every room.

8 Private Accommodation Rooms

The AC202 floor plan contains eight individual accommodation rooms, with four rooms positioned on each side of the internal corridor.

Each room is designed for single occupancy and provides a private living space suitable for staff, engineers, supervisors or other project personnel.

Based on the illustrated configuration, the building provides accommodation for approximately eight occupants.

Room Layout & Furniture

Each room is arranged as an independent living space with practical furniture for daily project accommodation.

The illustrated configuration includes a single bed, desk, chair and storage furniture within each room.

Furniture packages, finishes and storage arrangements can be adapted according to the required accommodation standard and personnel category.

Private En-Suite Bathrooms

One of the main advantages of AC202 is that every accommodation room includes its own dedicated sanitary facility.

In the illustrated layout, each en-suite area includes a toilet, washbasin and shower, allowing occupants to use private bathroom facilities without relying on shared sanitary blocks.

This arrangement makes AC202 particularly suitable for engineers, supervisors, consultants and staff who require a higher level of privacy and convenience.

Central Internal Corridor

A continuous internal corridor runs through the center of the building and provides access to all eight accommodation rooms.

This protected circulation layout allows occupants to move between rooms and building exits without relying on external walkways.

The corridor also creates a clear separation between the two rows of rooms and contributes to an organized accommodation layout.

Building Configuration

Model AC202
Building Type Single-storey en-suite modular accommodation building
Approximate Dimensions 9.60 × 13.80 m
Approximate Floor Area 132 m²
Number of Rooms 8 private accommodation rooms
Typical Occupancy 1 occupant per room
Potential Capacity Approximately 8 occupants
Sanitary Arrangement Private en-suite bathroom for each room
Circulation Central internal corridor

Designed for Staff & Engineer Accommodation

AC202 is particularly suitable for projects requiring private, well-organized accommodation for professional and technical personnel.

  • Engineer accommodation
  • Supervisor accommodation
  • Consultant housing
  • Staff accommodation
  • Management accommodation
  • Construction camps
  • Infrastructure projects
  • Industrial projects
  • Energy and mining projects
  • Remote project locations

Purpose-Built Modular Accommodation

AC202 is manufactured as a purpose-built modular accommodation building rather than a converted shipping container.

This allows room dimensions, bathrooms, corridor width, doors, windows, internal partitions and technical systems to be planned specifically around accommodation requirements.

Modular Structural System

AC202 can be manufactured using an engineered modular steel structural system combined with insulated wall and roof panels, internal partitions, insulated doors and windows and durable interior finishes.

Structural and architectural specifications can be adapted according to the project location, climate, destination requirements and intended accommodation standard.

Thermal Insulation & Building Envelope

Wall and roof systems can be specified according to the environmental conditions at the destination.

Insulated sandwich panels may use EPS, polyurethane or rock wool cores depending on thermal, acoustic, fire-performance and project requirements.

Doors, windows, roofing and module joints are coordinated to create a complete building envelope suitable for occupied accommodation.

Electrical, Plumbing & HVAC Systems

Electrical and plumbing installations can be integrated during factory production to reduce the amount of work required after delivery.

Electrical systems can include room and corridor lighting, power outlets, switches, distribution equipment and provisions for air-conditioning or heating.

Because each room includes an en-suite bathroom, water-supply and wastewater systems are coordinated with the repeated room layout during the design and manufacturing stages.

Customization Options

AC202 can be adapted according to personnel category, accommodation standard and project-specific requirements.

Furniture, interior finishes, sanitary fixtures, insulation levels, flooring, doors, windows, electrical systems, plumbing and HVAC provisions can all be selected according to the project specification.

Transportation & Installation

The building is manufactured as modular sections and transported to the destination for assembly on prepared foundations or supports.

Installation typically includes module positioning, structural connections, joint sealing and final connection of electrical, water, wastewater and HVAC systems.

Transportation dimensions, lifting requirements and site installation sequence are coordinated according to the final project configuration.

Product Specifications

Product 8-Room En-Suite Accommodation Building
Model AC202
Building Configuration Single storey
Approximate Dimensions 9.60 × 13.80 m
Approximate Floor Area 132 m²
Room Configuration Private single-occupancy rooms
Number of Rooms 8
Typical Occupancy 1 occupant per room
Potential Capacity Approximately 8 occupants
Sanitary Facilities Private en-suite bathroom in each room
Circulation Central internal corridor
Structure Engineered modular steel frame
Walls & Roof Insulated sandwich-panel system
Typical Use Staff, engineer and project personnel accommodation
Customization Available according to project requirements

Request an AC202 Project Proposal

Send us your project location, required accommodation capacity, personnel category and technical specifications to develop an AC202 configuration suited to your project.

Request a Project Proposal