AC201 is a two-storey modular accommodation building manufactured by Prefabex for staff, engineers, supervisors and project personnel requiring private rooms within a compact and organized accommodation structure.
The illustrated configuration measures approximately 24.00 m in length and 3.90 m in overall depth and provides eight individual accommodation rooms on each floor. When the same layout is repeated across both levels, the building provides a total of approximately 16 private rooms.
Its two-storey arrangement makes AC201 particularly suitable for construction camps, infrastructure projects, industrial sites and remote locations where accommodation capacity needs to be increased without significantly expanding the building footprint.
AC201 is part of the Accommodation Containers range by Prefabex, developed specifically for workforce housing and project-site accommodation.
AC201 combines private accommodation rooms, shared sanitary facilities and external circulation within one purpose-built modular building.
The layout is suitable for personnel who require greater privacy than conventional shared dormitory accommodation while allowing multiple rooms to be organized efficiently within a relatively narrow building footprint.
The illustrated AC201 floor plan contains eight individual accommodation rooms arranged along the length of the building.
Each room is designed for one occupant and includes a sleeping area with space for practical furniture and personal storage.
If the same configuration is used on both levels, AC201 provides approximately 16 private rooms and accommodation for up to 16 personnel.
The floor plan groups accommodation rooms in pairs, with shared sanitary facilities positioned between adjoining rooms.
This arrangement provides convenient access to sanitary facilities while concentrating plumbing and drainage services into organized wet-service zones.
In the illustrated layout, four shared sanitary areas serve the eight accommodation rooms on each floor.
Fixture arrangements and sanitary specifications can be adapted according to project requirements and the required accommodation standard.
| Model | AC201 |
|---|---|
| Building Type | Two-storey modular accommodation building |
| Number of Storeys | 2 |
| Approximate Length | 24.00 m |
| Approximate Overall Depth | 3.90 m |
| Rooms per Floor | 8 private accommodation rooms |
| Potential Total Rooms | Approximately 16 rooms across two identical floors |
| Typical Occupancy | 1 occupant per room |
| Potential Total Capacity | Approximately 16 occupants |
| Sanitary Arrangement | Shared sanitary facilities between paired rooms |
| Circulation | External walkway with external staircase access |
Both floors are accessed from external circulation areas positioned along the front of the accommodation rooms.
The upper level uses an elevated steel walkway with guardrails, while an external staircase provides vertical access between the two floors.
This arrangement keeps internal floor area focused on accommodation rooms and sanitary facilities while providing direct access to each room.
The two-storey configuration allows AC201 to provide twice the room capacity of a comparable single-level layout without requiring twice the ground area.
This makes the building particularly useful where site space is restricted or where accommodation must remain close to offices, dining facilities and other project infrastructure.
AC201 is manufactured as a purpose-built modular accommodation building rather than a converted shipping container.
This allows room dimensions, sanitary facilities, doors, windows, structural connections, walkways and building services to be planned specifically around personnel accommodation.
AC201 can be manufactured using engineered modular steel frames designed to operate together as a complete two-storey building.
Depending on the project specification, the structure can incorporate galvanized steel framing, insulated sandwich-panel walls and roofing, internal partitions, insulated doors and windows, durable flooring, external steel walkways, guardrails and staircase components.
Structural design for the two-storey configuration considers vertical loads, module connections, walkway loads, staircase access and overall building stability.
Wall and roof specifications can be adapted according to the climate and operating conditions at the project destination.
Insulated sandwich panels can use EPS, polyurethane or rock wool cores depending on thermal, acoustic and fire-performance requirements.
Doors, windows, roofing details and module joints are coordinated to create a functional and continuous building envelope after installation.
Electrical and plumbing installations can be integrated during factory production to reduce the amount of work required at the project site.
Depending on project requirements, systems can include room lighting, power outlets, switches, distribution equipment, water-supply lines, wastewater connections and provisions for air-conditioning or heating.
Grouping sanitary facilities between paired rooms allows plumbing and drainage routes to be concentrated within repeated service zones.
Each accommodation room can be furnished according to the intended personnel category and required project standard.
Typical furniture can include a single bed, wardrobe, bedside unit, desk, chair and personal storage.
Flooring, lighting, wall finishes, sanitary fixtures and furniture specifications can also be adapted according to project requirements.
AC201 can be adapted according to workforce requirements, destination conditions and the required accommodation standard.
Possible changes include furniture arrangements, sanitary fixtures, insulation levels, flooring, windows, doors, internal finishes, electrical systems, plumbing and HVAC provisions.
AC201 is manufactured as modular sections and transported to the project site for assembly on prepared foundations or supports.
Installation typically includes module positioning, structural connections, upper-floor assembly, walkway installation, staircase installation, joint sealing and final connection of electrical and plumbing systems.
Transportation dimensions, lifting equipment and installation sequence should be coordinated according to the final building configuration and project location.
| Product | Two-Storey Modular Accommodation Building |
|---|---|
| Model | AC201 |
| Building Configuration | Two storeys |
| Approximate Dimensions | 24.00 × 3.90 m per illustrated floor layout |
| Room Configuration | Private single-occupancy rooms |
| Rooms per Floor | 8 rooms |
| Potential Total Rooms | Approximately 16 rooms |
| Typical Occupancy | 1 occupant per room |
| Potential Total Capacity | Approximately 16 occupants |
| Sanitary Facilities | Shared sanitary facilities between paired rooms |
| Access | External walkways and external staircase |
| Structure | Engineered modular steel frame |
| Walls & Roof | Insulated sandwich-panel system |
| Typical Use | Staff, engineer and project personnel accommodation |
| Customization | Available according to project requirements |
Send us your project location, required accommodation capacity, personnel category and technical specifications to develop an AC201 configuration suited to your project.
Request a Project Proposal